TCS OS COMMANDS LIST

Conventions used in commands:
<mandatory field> = indicates a mandatory field to be typed after the command
[optional field] = indicates an optional field, that can be omitted

Command: #SHD
Description: Read/Write the hysteresis in degrees for the ChronoThermostat option that is the difference in temperature needed before the TCS will activate or deactivate the output
Sintax:
  • #SHD?
    Query current value
  • #SHD[=]<x.x>
    Set temperature hysteresis value from 0.0 to 3.0
  • Mandatory fields:
  • <x.x> value indicating temperature hysteresis from 0.0 to 3.0
  • Optional fields:
  • [=] can be used to improve readability
  • Examples:
  • #SHD?
  • #SHD=0.5
  • Default value after #INI: 0.0
    Default value after reset: Unchanged
    Command availability Command line and SMS
    ADMIN Password privileges: Read/Write
    USER Password privileges: Read
    Notes: Command available only if the Chronothermostat option is installed
    Requires TCS OS version: 5.1 or later