we don't just imagine things, we make them!
TCS_35 temperature adjustment instructions
red line
English SUPPORT Order Form TCS HOME
TCS 3.5 temperature adjustment instructions


Every TCs 3.5 must be matched to its probe to ensure maximum accuracy.
If you change the probe or the board you will need to adjus the trimmer on the board, please follow these instructions:
  • 1- Locate the adjustment trimmer and the probe connector.
  • 2- Use a multimeter with 0.001V accuracy and measure between red and black wires
  • 3- Put the probe in a temperature that you know and allow it to stabilize
  • 3- The voltage you read must be the 2.982 at 25 degrees centigrade or anyway 2.732 at 0 degrees increasing 0.010 V at each degree. As an example, at 10 degrees you will have to read 2.832, at 11 degrees 2.842 and so on.
  • 4- Use the Adjustment trimmer to adjust to the correct temperature reading as indicated above.


  • Important: don't touch the other trimmer!

     
    made in italy with love 
	by dps-promatic
     ©2001 DPS-Promatic srl
     (Copyright & privacy)
     Last modified:2008/03/11:19:47:33
    DPS-Promatic srl - via Edison 21, 47100 Forlì, Italy 
    P.I. 01519970402 Fax+39-0543-725274
    Contact us... 
    312