we don't just imagine things, we make them!
TCS 3.5 help on line: basic information
red line
English SUPPORT Order Form TCS HOME
TCS 3.5 on-line instructions



  Temperature management

TCS allows for easy measurement of temperature from -25° to +100°.
In order to do this you need to purchase the temperature management option when you buy the board together with a temperature probe. We have 2 models available, one is for use in air and one is for use in liquids. Accuracy is 1° Celsius.

Once the probe is connected you can inquire for Temperature sending the following SMS command:
#PWD123456#TMP?
You will receive an SMS with temperature value and other related alarm settings.


Setting temperature Alarms:

You can set lower and upper temperature limit so the TCS will send the ALARM message and the temperature value to the GSM number(s) indicated in the matrix for INPUT 9 ( temperature). The Alarm will be sent when temperature is below lower limit or above upper limit. You can set lower and upper limit also by SMS with the following command:
#PWD123456#TMPON,0,50
The above command sets lower limit at 0° and upper limit at +50°.
Temperature alarm can be enabled/disabled with the command #TMPON or #TMPOFF.
Default values are -25°/+100°, temperature alarm disabled.



Chrono-thermostat function

This is a special feature that can be purchased as an option that allows automatic control of a temperature in a room with daily steps, for 1 week, that can be updated via SMS. It works in the range 5-30 degrees Celsius. With this software option you can send an SMS that sets the temperature for 4 intervals each day, 7 days a week, individually programmed.

Using the command:
#DAY[1234567]#STP HH:MM gc HH:MM gc HH:MM gc HH:MM gc

You can set the temperature for one or more days (1=monday) for (up to) 4 time periods.

Example:
#DAY1345#STP=08:00 22.4,16:15 18
Sets temperature periods for Monday,Wednesday,Thursday and Friday.
In the above days temperature is set at 22.4 degrees C. at 08:00 and at 18 degrees at 16:15

TCS Chrono-thermostat has a Winter/Summer software switch and controls the temperature via output-7.
It will send alarms if temperature goes below or above 2 programmed thresholds.
It is possible to program an hysteresis based on temperature or on delay.

With Chrono-Thermostat option temperature range is limited to +5/+30° C with a division of 0,2°C.

NOTE: You can use the #CTO command to set another output pin, other than ouput 7. It can be convenient to use ouput 8 because it has already a relay that can stand up to MAX 48VAC, 500ma. Of course if you use Output 8 you can't use the gate opener function or a conflict would occur.

 
made in italy with love 
	by dps-promatic
 ©2001 DPS-Promatic srl
 (Copyright & privacy)
 Last modified:2004/02/22:10:36:45
DPS-Promatic srl - via Edison 21, 47100 Forlì, Italy 
P.I. 01519970402 Fax+39-0543-725274
Contact us... 
12340